TERMINAL TYPE AND QUANTITY | 10 TURRET |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL OR |
| 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| 20.00 AC VOLTS NOMINAL OR |
| 34.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING CURRENT | 870.0 MILLIAMPERES AC MINIMUM AND |
| 1.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY WIDTH | 2.360 INCHES MINIMUM AND |
| 2.440 INCHES MAXIMUM |
OVERALL LENGTH | 2.900 INCHES NOMINAL |
OVERALL HEIGHT | 1.450 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | TRANSFORMER IS DESIGNED TO RUN DIFFERENT COMBINATIONS OF WYE TO DELTA OR DELTA TO WYE |
TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |