1560-01-317-3096 COVER,ACCESS Index 5950-01-317-3098 REACTOR

National Stock Number:
5950-01-317-3097

Federal Supply Class:
5950

National Item Identification Number:
013173097

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
315-14381-0195266OECO, LLC
86221082577RAYTHEON COMPANY
986285-2B82577RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT1.820 INCHES MAXIMUM
BODY LENGTH2.500 INCHES MAXIMUM
BODY WIDTH2.030 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY FIRST CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.590 INCHES MINIMUM AND 1.610 INCHES MAXIMUM SINGLE MOUNTING FACILITY SECOND CENTER GROUP
DC RESISTANCE RATING IN OHMS0.00015 SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING20.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING3.50 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING
INDUCTANCE TYPEFIXED
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY4 ALL GROUPINGS
MOUNTING HOLE DIAMETER0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM SECOND GROUP
MOUNTING METHODTHREADED HOLE(S) AND UNTHREADED HOLE(S) SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES FIRST GROUP
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TEST DATA DOCUMENT82577-986285 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) FIRST GROUP
WINDING OPERATING CURRENT282.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT