| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.100 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| DC RESISTANCE RATING IN OHMS | 2.200 SINGLE COMPONENT SINGLE PRIMARY |
| DC RESISTANCE RATING IN OHMS | 2.700 SINGLE COMPONENT SINGLE SECONDARY |
| FREQUENCY RATING | 75.0 KILOHERTZ MINIMUM AND 1.0 MEGAHERTZ MAXIMUM SINGLE COMPONENT |
| IMPEDANCE RATING IN OHMS | 3000.0 MINIMUM SINGLE COMPONENT SINGLE SECONDARY |
| INCLOSURE TYPE | FULLY INCLOSED |
| OVERALL HEIGHT | 0.250 INCHES MAXIMUM |
| OVERALL LENGTH | 0.500 INCHES MAXIMUM |
| OVERALL WIDTH | 0.350 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| MOUNTING METHOD | TERMINAL SINGLE GROUP |
| PRIMARY TO SECONDARY TURN RATIO | 1 TO 1-41/100 SINGLE COMPONENT |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-21038/27 GOVERNMENT SPECIFICATION |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
| TEST DATA DOCUMENT | 81349-MIL-PRF-21038 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |