| BODY HEIGHT | 1.450 INCHES MAXIMUM |
| BODY LENGTH | 2.250 INCHES MAXIMUM |
| BODY WIDTH | 1.750 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.400 INCHES MINIMUM AND 1.440 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.160 INCHES MINIMUM AND 1.200 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | OPEN |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MAXIMUM OPERATING TEMP | 155.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING METHOD | THREADED HOLE(S) SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 15.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING CURRENT | 2.25 AMPERES DC NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS MINIMUM AND 199.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 13.00 DC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 26.00 DC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| WINDING POWER RATING | 58.5 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| WINDING POWER RATING | 0.2 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| TERMINAL TYPE AND QUANTITY | 9 TAB, SOLDER LUG |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |