5950-01-257-9286 TRANSFORMER,POWER Index 6220-01-257-9288 LIGHT,NAVIGATIONAL,AIRCRAFT

National Stock Number:
5950-01-257-9287

Federal Supply Class:
5950

National Item Identification Number:
012579287

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
245B955H0197942NORTHROP GRUMMAN SYSTEMS CORPORATION
740102PC9530086L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC.
TF4SX02YY81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.880 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.630 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT3.590 INCHES NOMINAL
OVERALL LENGTH3.720 INCHES NOMINAL
OVERALL WIDTH2.470 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 ALL GROUPINGS
MOUNTING HOLE DIAMETER0.201 INCHES NOMINAL SECOND GROUP
MOUNTING METHODTHREADED STUD(S) FIRST GROUP
MOUNTING METHODUNTHREADED HOLE(S) SECOND GROUP
NOMINAL THREAD SIZE0.164 INCHES FIRST GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT0.53 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT0.53 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT0.9 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE21.50 AC VOLTS MINIMUM AND 23.00 AC VOLTS MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE28.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
TERMINAL TYPE AND QUANTITY12 THREADED STUD
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) FIRST GROUP