5950-01-256-1571 TRANSFORMER,POWER Index 5950-01-256-1574 TRANSFORMER,POWER

National Stock Number:
5950-01-256-1572

Federal Supply Class:
5950

National Item Identification Number:
012561572

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
2901711-00010VCT0SUPERIOR MAGNETICS
2901711-189870BERKSHIRE TRANSFORMER
PEI 770213483PRECISION ELECTRONICS, INC
PEI770213483PRECISION ELECTRONICS, INC
2901711-195266OECO, LLC
2901711-196214RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT2.450 INCHES MAXIMUM
BODY LENGTH1.800 INCHES MAXIMUM
BODY WIDTH1.950 INCHES MAXIMUM
DISTANCE BETWEEN MOUNTING FACILITY CENTERS2.032 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SIX PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODTHREADED HOLE(S) SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.0 AMPERES DC NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE11.50 DC VOLTS MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE187.00 AC VOLTS MINIMUM AND 211.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE26.00 DC VOLTS MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE AND MOUNTING SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY9 PIN
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
TRANSFORMER WINDING CONNECTION TYPEWYE-DELTA