5910-01-251-6883 CAPACITOR Index 5325-01-251-6885 FASTENER ASSEMBLY,TURNLOCK

National Stock Number:
5950-01-251-6884

Federal Supply Class:
5950

National Item Identification Number:
012516884

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
653598-182577RAYTHEON COMPANY
WE-368915634MAGNETIKA INC
WE-368926543WEMS ELECTRONICS TRANSFORMER GROUP


Techincal Specification:
BODY WIDTH3.000 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING20.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT1.300 INCHES MAXIMUM
OVERALL LENGTH3.100 INCHES MAXIMUM
MAXIMUM OPERATING TEMP155.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.183 INCHES MINIMUM AND 0.193 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
SPECIAL FEATURES1 PRIMARY WINDING; 5 SECONDARY WINDINGS
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE156.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE40.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE48.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE60.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE70.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY23 TURRET