5340-01-248-9806 BRACKET,ANGLE Index 5950-01-248-9808 TRANSFORMER,POWER

National Stock Number:
5950-01-248-9807

Federal Supply Class:
5950

National Item Identification Number:
012489807

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
10005107690BAE SYSTEMS CONTROLS INC
4141103550VANGUARD ELECTRONICS, LLC
632930-0107690BAE SYSTEMS CONTROLS INC
M-12509798PAYNE MAGNETICS, INC.
ITP-1629-609969VISHAY DALE ELECTRONICS, INC.
632930-0189954BAE SYSTEMS CONTROLS INC.


Techincal Specification:
FREQUENCY RATING55.00 KILOHERTZ MINIMUM AND 80.00 KILOHERTZ MAXIMUM SINGLE COMPONENT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL DIAMETER1.570 INCHES NOMINAL
OVERALL LENGTH0.970 INCHES NOMINAL
MAXIMUM OPERATING TEMP155.0 CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING METHODTERMINAL AND UNTHREADED HOLE(S) SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
SPECIAL FEATURES1 PRIMARY WINDING; 5 SECONDARY WINDINGS
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT141.4 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT353.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT4.95 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT2.48 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE1.32 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE1.32 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE150.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE4.07 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE3.45 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
TERMINAL TYPE AND QUANTITY2 TURRET AND 10 PIN
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP