5950-01-248-5946 TRANSFORMER,POWER Index 5950-01-248-5948 TRANSFORMER,POWER AUTOTRANSFORME

National Stock Number:
5950-01-248-5947

Federal Supply Class:
5950

National Item Identification Number:
012485947

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
10186025656DBP MICROWAVE INC. DBA
2005764053COILTRON INC
7136812-106481NORTHROP GRUMMAN SYSTEMS CORPORATION
7136812-117863LITTON SYSTEMS INC GUIDANCE AND CONTROL SYSTEMS DIV


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.344 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT1.900 INCHES MAXIMUM
OVERALL LENGTH1.800 INCHES NOMINAL
OVERALL WIDTH1.520 INCHES NOMINAL
MAXIMUM OPERATING TEMP155.0 CELSIUS
MAXIMUM TRANSFORMER POWER RATING27.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED HOLE(S) SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT5.0 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT20.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT235.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE92.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING POWER RATING1.84 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
WINDING POWER RATING25.0 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
WINDING POWER RATING27.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY6 TURRET
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP