5950-01-222-0806 COIL,ELECTRICAL Index 5950-01-222-0808 TRANSFORMER,POWER

National Stock Number:
5950-01-222-0807

Federal Supply Class:
5950

National Item Identification Number:
012220807

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
13203309-0127963GENERAL DYNAMICS INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
13203309-013CYA2GENERAL DYNAMICS MISSION SYSTEMS, INC.
14455700-0227963GENERAL DYNAMICS INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
14455700-023CYA2GENERAL DYNAMICS MISSION SYSTEMS, INC.
6708069080023VISHAY HIREL SYSTEMS LLC


Techincal Specification:
TERMINAL TYPE AND QUANTITY13 TURRET
WINDING OPERATING VOLTAGE308.00 AC MILLIVOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
462.00 AC MILLIVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
1.15 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
2.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT18.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
5.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
2.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
3.5 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING5.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
2.3 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
2.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
7.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING1.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.485 INCHES MINIMUM AND
2.515 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.110 INCHES MINIMUM AND
1.140 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEOPEN
OVERALL LENGTH2.910 INCHES MINIMUM AND
2.970 INCHES MAXIMUM
OVERALL HEIGHT1.850 INCHES MAXIMUM
OVERALL WIDTH2.270 INCHES MINIMUM AND
2.330 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESFIRST SECONDARY CENTER TAP SPLIT INTO TWO TERMINALS
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS