5950-01-185-5735 REACTOR Index 5950-01-185-5737 REACTOR

National Stock Number:
5950-01-185-5736

Federal Supply Class:
5950

National Item Identification Number:
011855736

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
57826200-0227963GENERAL DYNAMICS INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
57826200-023CYA2GENERAL DYNAMICS MISSION SYSTEMS, INC.


Techincal Specification:
BODY OUTSIDE DIAMETER2.740 INCHES MINIMUM AND 2.770 INCHES MAXIMUM
FREQUENCY RATING1.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL LENGTH1.350 INCHES MINIMUM AND 1.410 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING HOLE DIAMETER0.170 INCHES MINIMUM AND 0.230 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE13.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE353.00 AC MILLIVOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY13 WIRE LEAD


Click here to Register for Free 30-day Trial