5950-01-184-1485 TRANSFORMER,PULSE Index 5955-01-184-1488 CRYSTAL UNIT,QUARTZ

National Stock Number:
5950-01-184-1486

Federal Supply Class:
5950

National Item Identification Number:
011841486

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
4043924-050106845RAYTHEON COMPANY
4045996-070106845RAYTHEON COMPANY
4045996-070157812RAYCOM ELECTRONICS INC
500-25-2993292CENTRAL COIL CO INC


Techincal Specification:
ADJUSTMENT DEVICE DRIVE TYPESLOTTED SCREW SINGLE COMPONENT
ADJUSTMENT METHOD AND QUANTITY1 ADJUSTABLE CORE SINGLE COMPONENT
BODY LENGTH0.500 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.158 INCHES NOMINAL
COIL FORM TYPEAIR WOUND SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INDUCTANCE RATING0.14 MICROHENRIES MINIMUM AND 0.22 MICROHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING
MOUNTING METHODTERMINAL SINGLE GROUP
QUALITY FACTOR80 MINIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
TURN QUANTITY4-1/2 SINGLE COMPONENT SINGLE WINDING
WINDING CONDUCTOR SIZE0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING
TERMINAL TYPE AND QUANTITY2 WIRE LEAD