5950-01-177-9544 TRANSFORMER,POWER Index 5950-01-177-9546 TRANSFORMER,POWER

National Stock Number:
5950-01-177-9545

Federal Supply Class:
5950

National Item Identification Number:
011779545

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
24-0695-0011402HISONIC, LLC
27129-207388TOROTEL, INC.
28322-107388TOROTEL, INC.
657738-182577RAYTHEON COMPANY
PA60012/14-182577RAYTHEON COMPANY
310-14553-0195266OECO, LLC


Techincal Specification:
TERMINAL TYPE AND QUANTITY18 WIRE LEAD
WINDING OPERATING VOLTAGE20.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
54.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
101.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
20.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
54.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT4.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
250.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
2.5 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
1.0 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING80.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
13.5 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
252.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
20.2 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING40.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
5 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTERMINAL SINGLE GROUP
INCLOSURE TYPEFULLY INCLOSED
BODY LENGTH0.875 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.475 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING AND FIVE SECONDARY WINDINGS


Click here to Register for Free 30-day Trial