| TERMINAL TYPE AND QUANTITY | 26 TURRET |
| WINDING OPERATING VOLTAGE | 21.60 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 22.50 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 25.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 5.3 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| 4.8 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| 2.3 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| 300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| WINDING POWER RATING | 198.1 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| 186.8 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| 39.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| 13.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 8 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE AND |
| THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.740 INCHES MINIMUM AND |
| 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.240 INCHES MINIMUM AND |
| 2.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 4.060 INCHES MAXIMUM |
| BODY HEIGHT | 2.440 INCHES MAXIMUM |
| BODY WIDTH | 3.320 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.659 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | ONE PRIMARY WINDING; EIGHT SECONDARY WINDINGS |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
| MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |