| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 2.750 INCHES MAXIMUM |
| OVERALL LENGTH | 3.000 INCHES MAXIMUM |
| OVERALL WIDTH | 3.000 INCHES NOMINAL |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.191 INCHES MINIMUM AND 0.201 INCHES MAXIMUM SINGLE GROUP |
| MOUNTING METHOD | UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 350.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| WINDING OPERATING CURRENT | 350.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| WINDING OPERATING CURRENT | 800.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING CURRENT | 800.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 107.35 AC VOLTS MINIMUM AND 118.65 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 21.17 AC VOLTS MINIMUM AND 22.03 AC VOLTS MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING VOLTAGE | 21.17 AC VOLTS MINIMUM AND 22.03 AC VOLTS MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 16.76 AC VOLTS MINIMUM AND 17.44 AC VOLTS MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| WINDING OPERATING VOLTAGE | 16.76 AC VOLTS MINIMUM AND 17.44 AC VOLTS MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| WINDING POWER RATING | 5.985 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY |
| WINDING POWER RATING | 5.985 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| WINDING POWER RATING | 17.28 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| WINDING POWER RATING | 17.28 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| TERMINAL TYPE AND QUANTITY | 15 SOLDER STUD |