5999-01-123-0659 CONTACT ASSEMBLY,ELECTRICAL Index 5910-01-123-0662 CAPACITOR ASSEMBLY

National Stock Number:
5950-01-123-0660

Federal Supply Class:
5950

National Item Identification Number:
011230660

Description:
TRANSFORMER ASSEMBLY

Detail:
TWO OR MORE SEPARABLE TRANSFORMER (AS MODIFIED) ON A COMMON MOUNTING OR MOUNTED ON EACH OTHER.


Manufacturer Information:
1136455196SORA POWER INC.
321-18050-0195266OECO, LLC
861897E82577RAYTHEON COMPANY
984882-2B82577RAYTHEON COMPANY
321-18050-0495266OECO, LLC
ST3085297102STERLING TRANSFORMER CORP


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS5.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING10.0 KILOHERTZ NOMINAL ALL COMPONENTS
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT3.570 INCHES MAXIMUM
OVERALL LENGTH4.750 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING HOLE DIAMETER0.187 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
RATING METHODELECTRICAL ALL COMPONENTS ALL PRIMARY
RATING METHODELECTRICAL ALL COMPONENTS ALL SECONDARY
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SECOND COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY FIRST COMPONENT
WINDING OPERATING CURRENT1.2 AMPERES AC MAXIMUM SECOND COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT10.0 MILLIAMPERES AC MAXIMUM SECOND COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT35.0 MILLIAMPERES AC MAXIMUM FIRST COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT35.0 MILLIAMPERES AC MAXIMUM SECOND COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT3.0 AMPERES AC MAXIMUM FIRST COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES AC MAXIMUM FIRST COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES AC MAXIMUM FIRST COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE12.02 AC VOLTS NOMINAL FIRST COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE12.02 AC VOLTS NOMINAL FIRST COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE130.00 DC VOLTS NOMINAL AND 133.50 DC VOLTS NOMINAL AND 137.00 DC VOLTS NOMINAL SECOND COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE149.88 AC VOLTS NOMINAL FIRST COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE178.16 AC VOLTS NOMINAL AND 195.83 AC VOLTS NOMINAL AND 213.51 AC VOLTS NOMINAL SECOND COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE28.28 AC VOLTS NOMINAL FIRST COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE32.52 AC VOLTS NOMINAL SECOND COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE70.70 AC VOLTS NOMINAL FIRST COMPONENT SECOND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS
TERMINAL TYPE AND QUANTITY35 WIRE LEAD