| BODY WIDTH | 1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.170 INCHES MINIMUM AND 3.190 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.920 INCHES MINIMUM AND 0.940 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 1.050 INCHES MINIMUM AND 1.090 INCHES MAXIMUM |
| OVERALL LENGTH | 3.480 INCHES MINIMUM AND 3.520 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.143 INCHES MINIMUM AND 0.149 INCHES MAXIMUM SINGLE GROUP |
| MOUNTING METHOD | UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | SECONDARY TERMINALS SPLIT AND BROUGHT OUT TO TWO TERMINALS EACH |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 529.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING POWER RATING | 13.8 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
| TERMINAL TYPE AND QUANTITY | 7 TURRET |
| TEST DATA DOCUMENT | 06481-905867 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |