5930-01-117-6785 SWITCH,SENSITIVE Index 5950-01-117-6788 TRANSFORMER,POWER

National Stock Number:
5950-01-117-6787

Federal Supply Class:
5950

National Item Identification Number:
011176787

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1100755196SORA POWER INC.
L50400045436090LOCKHEED MARTIN LIBRASCOPE CORP


Techincal Specification:
TERMINAL TYPE AND QUANTITY12 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE54.70 AC VOLTS MINIMUM AND
59.30 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY
21.10 AC VOLTS MINIMUM AND
22.88 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY
6.05 AC VOLTS MINIMUM AND
6.34 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY
103.50 AC VOLTS MINIMUM AND
126.50 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT120.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
FREQUENCY RATING380.0 HERTZ MINIMUM AND
420.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE AND
THREE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.156 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.433 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEOPEN
BODY LENGTH3.500 INCHES NOMINAL
BODY HEIGHT1.375 INCHES NOMINAL
BODY WIDTH1.620 INCHES NOMINAL
OVERALL LENGTH3.500 INCHES NOMINAL
OVERALL HEIGHT1.375 INCHES NOMINAL
OVERALL WIDTH2.700 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA AND
DELTA-WYE