6130-01-115-1240 RELAY CARD ASSEMBLY Index 5950-01-115-1242 TRANSFORMER

National Stock Number:
5950-01-115-1241

Federal Supply Class:
5950

National Item Identification Number:
011151241

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
54911418731795EATON CORPORATION


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH7.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH8.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SIX PHASE SINGLE COMPONENT AND SIX PHASE TO SIX PHASE SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM TRANSFORMER POWER RATING68.8 KILOVOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.620 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODBRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
OVERALL HEIGHT25.000 INCHES NOMINAL
OVERALL LENGTH23.500 INCHES NOMINAL
OVERALL WIDTH10.420 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT164.7 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT177.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING CURRENT177.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE36.10 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE62.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE67.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING11.03 K1LOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING11.01 K1LOVOLT-AMPERES SINGLE COMPONENT 1ST PRIMARY
WINDING POWER RATING6.39 K1LOVOLT-AMPERES SINGLE COMPONENT 2ND PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY30 TAB, SOLDER LUG AND 1 WIRE LEAD
TRANSFORMER WINDING CONNECTION TYPEWYE-WYE