TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
03003840 ITEM 1278039LEICA INC SURVEYING AND PHOTOGRAMMETRY SYSTEMS DIV
4170134078039LEICA INC SURVEYING AND PHOTOGRAMMETRY SYSTEMS DIV


Techincal Specification:
BODY HEIGHT3.125 INCHES NOMINAL
BODY LENGTH3.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.093 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FEATURES PROVIDEDCOLOR CODED LEAD AND TINNED WIRE LEADS
FREQUENCY RATING50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODBRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE10.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE35.60 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE387.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY8 WIRE LEAD