5950-01-106-6133 TRANSFORMER,POWER Index 5915-01-106-6137 FILTER

National Stock Number:
5950-01-106-6134

Federal Supply Class:
5950

National Item Identification Number:
011066134

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1790687-50549671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES
8154816-111447L3 TECHNOLOGIES, INC.
PEI 943513483PRECISION ELECTRONICS, INC
8154816-149671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES


Techincal Specification:
TERMINAL TYPE AND QUANTITY12 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE2100.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
526.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT816.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
33.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
8.5 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING380.0 HERTZ MINIMUM AND
420.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHODFLANGE AND
UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.234 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.350 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
OVERALL LENGTH4.500 INCHES MAXIMUM
OVERALL HEIGHT3.820 INCHES MAXIMUM
OVERALL WIDTH3.600 INCHES MINIMUM AND
3.640 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
TRANSFORMER WINDING CONNECTION TYPEWYE-WYE
MAXIMUM OPERATING TEMP100.0 DEG CELSIUS