TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
WINDING OPERATING VOLTAGE | 110.00 AC VOLTS MINIMUM AND |
| 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| 220.00 AC VOLTS MINIMUM AND |
| 240.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY |
WINDING OPERATING CURRENT | 4.35 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
WINDING POWER RATING | 500.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
FREQUENCY RATING | 50.0 HERTZ NOMINAL OR |
| 60.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | BRACKET AND |
| SLOT SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING SLOT WIDTH | 0.219 INCHES NOMINAL SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 6.688 INCHES NOMINAL |
BODY HEIGHT | 4.188 INCHES NOMINAL |
BODY WIDTH | 4.938 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | TERMINAL OUTPUT SIDE OF TRANSFORMER HAVE 3 SCREW TERMINALS FOR MOUNTING A FUSE KIT IF NEEDED |