National Stock Number:
5950-01-104-5443

Federal Supply Class:
5950

National Item Identification Number:
011045443

Description:
TRANSFORMER,RADIO FREQUENCY

Detail:
An item having either a single tapped winding (autotransformer type), or two or more windings designed to furnish inductive reactance and/or transfer electrical energy in circuits by means of a magnetic field. It is so designed that its entire intended range of operations is above 20 Kilohertz (Kilocycles). The minimum value may extend into the audio frequency range (below 20 Kilohertz). It may include integral capacitors, coils, resistors, and adjustable tuning cores. For items having only two active terminals see COIL, RADIO FREQUENCY. Includes types having windings which may be moved with respect to each other. Excludes TRANSFORMER, DISCRIMINATOR.


Manufacturer Information:
1501G13030LOCKHEED MARTIN SIPPICAN, INC.
1511M13030LOCKHEED MARTIN SIPPICAN, INC.


Techincal Specification:
BODY LENGTH0.850 INCHES MAXIMUM
COIL FORM TYPESOLID SINGLE COMPONENT
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.185 INCHES MINIMUM AND 1.195 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING20.0 KILOHERTZ MINIMUM AND 250.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING9.00 MICROHENRIES NOMINAL SINGLE COMPONENT SECOND SECONDARY
INDUCTANCE RATING515.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY
INDUCTANCE RATING63.00 MILLIHENRIES NOMINAL SINGLE COMPONENT FIRST SECONDARY
MAXIMUM OPERATING TEMP85.0 CELSIUS
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
OVERALL DIAMETER1.201 INCHES MINIMUM AND 1.211 INCHES MAXIMUM
RATING METHODELECTRICAL SINGLE COMPONENT FIRST SECONDARY
RATING METHODELECTRICAL SINGLE COMPONENT SECOND SECONDARY
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE PRIMARY
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY7 PIN
TRANSFORMER FUNCTIONINPUT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT