5950-01-100-0718 TRANSFORMER,POWER Index 5950-01-100-0720 TRANSFORMER,POWER

National Stock Number:
5950-01-100-0719

Federal Supply Class:
5950

National Item Identification Number:
011000719

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
120-1038-0080009TEKTRONIX, INC.


Techincal Specification:
BODY HEIGHT3.500 INCHES NOMINAL
BODY LENGTH4.500 INCHES NOMINAL
BODY WIDTH3.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.219 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT0.094 AMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT10.0 AMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT2.5 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE100.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE16.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE330.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE34.90 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY16 WIRE LEAD AND 2 WIRE LOOP


Click here to Register for Free 30-day Trial