5930-01-098-4886 SWITCH,SENSITIVE Index 5950-01-098-4892 TRANSFORMER,POWER

National Stock Number:
5950-01-098-4890

Federal Supply Class:
5950

National Item Identification Number:
010984890

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
15M101G24226GOWANDA HOLDINGS, LLC
4425-6G59474JEFFERS ELECTRONICS INC
9100-33411LQK8KEYSIGHT TECHNOLOGIES, INC.
9100-334128480HEWLETT-PACKARD COMPANY
6-0282332159WEST CAP ARIZONA
9100-33417ZXR5KEYSIGHT TECHNOLOGIES INC
IM-4 1UH 2PCT09969VISHAY DALE ELECTRONICS, INC.


Techincal Specification:
COIL FORM TYPESOLID SINGLE COMPONENTSOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENTS0LID SINGLE COMPONENT
DC RESISTANCE RATING IN OHMS0.290 SINGLE COMPONENT SINGLE WINDING0.290 SINGLE COMPONENT SINGLE WINDING
FEATURES PROVIDEDTINNED WIRE LEADSTINNED WIRE LEADS
INCLOSURE TYPEFULLY INCLOSEDFULLY INCLOSED
INDUCTANCE RATING1.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING1.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
OVERALL DIAMETER0.146 INCHES MINIMUM AND 0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM0.166 INCHES MAXIMUM
OVERALL LENGTH0.365 INCHES MINIMUM AND 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM0.385 INCHES MAXIMUM
MAXIMUM OPERATING TEMP125.0 CELSIUS125.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUPTERMINAL SINGLE GROUP
QUALITY FACTOR50 MINIMUM SINGLE COMPONENT SINGLE WINDING50 MINIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDINGELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHED
SPECIAL FEATURESSUFFIX LETTER ON P/N DENOTES STD TOLERANCE OF 2 PCTSUFFIX LETTER ON P/N DENOTES STD TOLERANCE OF 2 PCT
WINDING CONDUCTOR SIZE0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING
WINDING OPERATING CURRENT830.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING830.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
TERMINAL TYPE AND QUANTITY2 WIRE LEAD2 WIRE LEAD