| TERMINAL TYPE AND QUANTITY | 3 TURRET |
| WINDING OPERATING CURRENT | 50.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.132 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 2.000 INCHES MAXIMUM |
| BODY HEIGHT | 2.000 INCHES MAXIMUM |
| BODY WIDTH | 0.780 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| MAXIMUM OPERATING TEMP | 65.0 DEG CELSIUS |