| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.204 INCHES MINIMUM AND 6.224 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.054 INCHES MINIMUM AND 4.074 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 1.550 INCHES MAXIMUM |
| OVERALL LENGTH | 6.640 INCHES MINIMUM AND 6.660 INCHES MAXIMUM |
| OVERALL WIDTH | 4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL SINGLE GROUP |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 5.7 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
| WINDING OPERATING VOLTAGE | 104.00 AC VOLTS MINIMUM AND 215.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 22.40 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| WINDING SHIELDING METHOD | CORE GROUNDED SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 10 TURRET |