5930-00-972-9361 SWITCH,TOGGLE Index 5935-00-972-9364 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5950-00-972-9362

Federal Supply Class:
5950

National Item Identification Number:
009729362

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
11187-111189KAISER AEROSPACE AND ELECTRONICS CORP PHOENIX ELECTRONICS PLANT
1197-111189KAISER AEROSPACE AND ELECTRONICS CORP PHOENIX ELECTRONICS PLANT
P1-1440653854MAGNESPEC INC
P1-1440695970MTE CORP MILWAUKEE TRANSFORMER CO


Techincal Specification:
TERMINAL TYPE AND QUANTITY14 WIRE HOOK
WINDING OPERATING VOLTAGE24.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
109.00 AC VOLTS NOMINAL AND
121.00 AC VOLTS NOMINAL AND
230.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT208.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
115.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
9.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING5.0 WATTS SINGLE COMPONENT 1ST SECONDARY
3.0 WATTS SINGLE COMPONENT 2ND SECONDARY
2.0 WATTS SINGLE COMPONENT 3RD SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODCORE GROUNDED AND BROUGHT OUT TO TERMINAL AND
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH1.563 INCHES MINIMUM AND
1.625 INCHES MAXIMUM
BODY WIDTH1.563 INCHES MINIMUM AND
1.625 INCHES MAXIMUM
OVERALL HEIGHT2.750 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED