3040-00-949-4877 COLLAR,SHAFT Index 5950-00-949-4883 REACTOR

National Stock Number:
5950-00-949-4881

Federal Supply Class:
5950

National Item Identification Number:
009494881

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
180108303956NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
TERMINAL TYPE AND QUANTITY4 SOLDER STUD
RATING METHODELECTRICAL SINGLE COMPONENT 1ST WINDING
ELECTRICAL SINGLE COMPONENT 2ND WINDING
WINDING QUANTITY2 SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
WINDING OPERATING CURRENT100.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING
200.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING
DC RESISTANCE RATING IN OHMS0.800 SINGLE COMPONENT 1ST WINDING
0.200 SINGLE COMPONENT 2ND WINDING
INDUCTANCE RATING68.00 MILLIHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING
17.00 MILLIHENRIES NOMINAL SINGLE COMPONENT 2ND WINDING
INDUCTANCE TYPEFIXED
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH32 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY LENGTH2.750 INCHES NOMINAL
BODY HEIGHT1.625 INCHES NOMINAL
BODY WIDTH1.625 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED