5950-00-947-4689 REACTOR Index 5915-00-947-4691 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5950-00-947-4690

Federal Supply Class:
5950

National Item Identification Number:
009474690

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
23676450508MAGNETIC COMPONENTS INC
24P23676498738HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS
531971L8V1MAGNETIKA INC
30-1014450508MAGNETIC COMPONENTS INC
5319753342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
24P236764REVB96253TRANSFORMER TECHNICIANS INC
89053472149ELECTRONIC TRANSFORMER CORP
89053480249BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
TF5VX03ZZ81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
T-6096396256THORDARSON INC


Techincal Specification:
TERMINAL TYPE AND QUANTITY17 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE152.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
50.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
35.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
12.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
56.00 AC VOLTS MINIMUM AND
112.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT60.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
11.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
110.0 MILLIAMPERES DC MINIMUM AND
120.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
86.0 MILLIAMPERES DC MINIMUM AND
235.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING320.0 HERTZ MINIMUM AND
480.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
5 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
OVERALL LENGTH2.375 INCHES MAXIMUM
OVERALL HEIGHT2.440 INCHES MAXIMUM
OVERALL WIDTH1.625 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURES5SECONDARY WINDINGS
MAXIMUM OPERATING TEMP155.0 DEG CELSIUS


Click here to Register for Free 30-day Trial