| TERMINAL TYPE AND QUANTITY | 25 TURRET |
| WINDING OPERATING VOLTAGE | 41.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
| 65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
| 346.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 3.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| WINDING OPERATING CURRENT | 84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| WINDING POWER RATING | 5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| 13.86 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| 1.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| 1.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND |
| 6 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE AND |
| THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
| MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
| 4 2ND GROUP |
| 4 3RD GROUP |
| 4 4TH GROUP |
| THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
| NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP |
| 0.112 INCHES 2ND GROUP |
| 0.112 INCHES 3RD GROUP |
| 0.164 INCHES 4TH GROUP |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.109 INCHES MINIMUM AND |
| 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM AND |
| 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
| 3.109 INCHES MINIMUM AND |
| 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
| 1.552 INCHES MINIMUM AND |
| 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM AND |
| 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
| 1.672 INCHES MINIMUM AND |
| 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
| 0.990 INCHES MINIMUM AND |
| 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 3.859 INCHES MINIMUM AND |
| 3.891 INCHES MAXIMUM |
| BODY WIDTH | 2.172 INCHES MINIMUM AND |
| 2.204 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.859 INCHES MINIMUM AND |
| 1.891 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | TWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS |
| TEST DATA DOCUMENT | 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |