5950-00-937-9525 TRANSFORMER,POWER Index 4130-00-937-9527 FILTER MEDIA,AIR CONDITIONING

National Stock Number:
5950-00-937-9526

Federal Supply Class:
5950

National Item Identification Number:
009379526

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
CT10162598330OECO, LLC
SM-C-54072280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
TERMINAL TYPE AND QUANTITY9 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE6.30 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
22.00 DC VOLTS MINIMUM AND
30.00 DC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT8.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING3.7 KILOHERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING3.0 WATTS SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY2 PRIMARY AND
1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH32 SINGLE GROUP
INCLOSURE TYPEFULLY INCLOSED
BODY OUTSIDE DIAMETER2.000 INCHES MAXIMUM
OVERALL LENGTH1.000 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
MAXIMUM OPERATING TEMP105.0 DEG CELSIUS