TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |
WINDING OPERATING VOLTAGE | 72.75 AC VOLTS MINIMUM AND |
| 77.25 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| 72.75 AC VOLTS MINIMUM AND |
| 77.25 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| 300.70 AC VOLTS MINIMUM AND |
| 319.30 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| 192.00 AC VOLTS MINIMUM AND |
| 202.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 325.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| 325.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| 140.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
FREQUENCY RATING | 6.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 3 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | TERMINAL SINGLE GROUP |
INCLOSURE TYPE | HERMETICALLY SEALED |
BODY LENGTH | 1.005 INCHES MINIMUM AND |
| 1.015 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 1.307 INCHES MINIMUM AND |
| 1.317 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TEST DATA DOCUMENT | 10001-2412390 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |