1560-00-918-4402 STUB ASSEMBLY,TRAILING EDGE Index 1615-00-918-4404 LINK SET,ROTARY WIN

National Stock Number:
5950-00-918-4403

Federal Supply Class:
5950

National Item Identification Number:
009184403

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
336-072-01007421L3HARRIS INTERSTATE ELECTRONICS CORPORATION
9100-01761LQK8KEYSIGHT TECHNOLOGIES, INC.
9100-017628480HEWLETT-PACKARD COMPANY
9100-01767ZXR5KEYSIGHT TECHNOLOGIES INC


Techincal Specification:
BODY HEIGHT3.250 INCHES MAXIMUM
BODY LENGTH4.750 INCHES MAXIMUM
BODY WIDTH3.875 INCHES MAXIMUM
FREQUENCY RATING50.0 HERTZ MINIMUM AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT20.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT20.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT65.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE12.60 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE12.60 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE170.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE195.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY


Click here to Register for Free 30-day Trial