4730-00-894-0337 BUSHING,PIPE Index 5950-00-894-0346 TRANSFORMER,POWER

National Stock Number:
5950-00-894-0344

Federal Supply Class:
5950

National Item Identification Number:
008940344

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
11242010-2617773BALLISTIC MISSILE DEFENSE SYSTEMS COMMAND
375-2236G263B150RAYTHEON COMPANY
375-2236G2649956RAYTHEON COMPANY
375-2236G2654X10RAYTHEON COMPANY
BP1499-2699800AMERICAN PRECISION INDUSTRIES INC.


Techincal Specification:
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
RATING METHODELECTRICAL AND
WINDING TURNS SINGLE COMPONENT SINGLE WINDING
INCLOSURE TYPEFULLY INCLOSED
TURN QUANTITY16 SINGLE COMPONENT SINGLE WINDING
WINDING CONDUCTOR SIZE0.00708 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING
WINDING OPERATING CURRENT800.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING0.332 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
QUALITY FACTOR60 MINIMUM SINGLE COMPONENT SINGLE WINDING
COIL FORM TYPESOLID SINGLE COMPONENT
MOUNTING METHODTERMINAL SINGLE GROUP
BODY LENGTH0.225 INCHES MINIMUM AND
0.310 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.105 INCHES MINIMUM AND
0.130 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
MAXIMUM OPERATING TEMP110.0 DEG CELSIUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONSALT SPRAY RESISTANT AND
VIBRATION PROOF