| BODY HEIGHT | 5.000 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.469 INCHES MINIMUM AND 4.531 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.219 INCHES MINIMUM AND 4.281 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| DC RESISTANCE RATING IN OHMS | 0.050 SINGLE COMPONENT SECOND CONTROL |
| DC RESISTANCE RATING IN OHMS | 0.580 SINGLE COMPONENT ALL PRIMARY |
| DC RESISTANCE RATING IN OHMS | 55.000 SINGLE COMPONENT FIRST CONTROL |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| OVERALL HEIGHT | 5.880 INCHES NOMINAL |
| OVERALL LENGTH | 6.190 INCHES NOMINAL |
| OVERALL WIDTH | 5.500 INCHES NOMINAL |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING METHOD | THREADED STUD(S) SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | CONTROL WINDING NO. 2 IS A FEEDBACK WINDING,TERMINALS 7 AND 8 |
| WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 2 CONTROL SINGLE COMPONENT |
| WINDING OPERATING VOLTAGE | 206.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 8 TURRET |
| THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |