4820-00-826-9678 VALVE,CHECK Index 4730-00-826-9680 PLUG,PIPE

National Stock Number:
5950-00-826-9679

Federal Supply Class:
5950

National Item Identification Number:
008269679

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
3330172149ELECTRONIC TRANSFORMER CORP
74585503P103538LOCKHEED MARTIN CORPORATION
9T35Y24103512GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT
7485503P103538LOCKHEED MARTIN CORPORATION
997500218876U S ARMY AVIATION AND MISSILE COMMAND
7485503P178792GENERAL ELECTRIC CO TRANSMITTER DIVISION
9T35Y24103538LOCKHEED MARTIN CORPORATION
B748550324446GENERAL ELECTRIC COMPANY
B748550324454GENERAL ELECTRIC CO ELECTRONIC COMPONENTS DIVISION OF ELECTRONIC ATOMIC AND DEFENSE SYSTEMS GROUP


Techincal Specification:
TERMINAL TYPE AND QUANTITY7 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL AND
120.00 AC VOLTS NOMINAL AND
126.00 AC VOLTS NOMINAL AND
132.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
6.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT2.3 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING54.0 HERTZ MINIMUM AND
66.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH32 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH2.625 INCHES MINIMUM AND
2.750 INCHES MAXIMUM
BODY HEIGHT3.688 INCHES MINIMUM AND
3.812 INCHES MAXIMUM
BODY WIDTH2.250 INCHES MINIMUM AND
2.375 INCHES MAXIMUM
OVERALL HEIGHT4.375 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
MAXIMUM OPERATING TEMP65.0 DEG CELSIUS


Click here to Register for Free 30-day Trial