| TERMINAL TYPE AND QUANTITY | 14 SOLDER STUD |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| 6.30 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| WINDING OPERATING CURRENT | 1.25 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| 6.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| 11.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| 600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| FREQUENCY RATING | 50.0 HERTZ MINIMUM AND |
| 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 4 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED STUD SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY LENGTH | 3.938 INCHES NOMINAL |
| BODY HEIGHT | 5.250 INCHES NOMINAL |
| BODY WIDTH | 3.375 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 02048 |
| DESIGN CONTROL REFERENCE | 96-442 |