5950-00-679-9503 REACTOR Index 5910-00-679-9505 CAPACITOR,FIXED,PAPER DIELECTRIC

National Stock Number:
5950-00-679-9504

Federal Supply Class:
5950

National Item Identification Number:
006799504

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
2654580089EMERSON ELECTRIC CO WHITE-RODGERS DIV
2654597520BASLER ELECTRIC CO
662-0278-0013499ROCKWELL COLLINS, INC.
E10265A80008ELECTRO ENGINEERING WORKS INC


Techincal Specification:
TERMINAL TYPE AND QUANTITY15 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE12.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
70.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
130.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
230.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
25.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING50.0 HERTZ NOMINAL OR
60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY2 PRIMARY AND
4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODFLANGE AND
UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
BODY LENGTH4.500 INCHES NOMINAL
BODY HEIGHT4.000 INCHES NOMINAL
BODY WIDTH3.375 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
THE MANUFACTURERS DATA
MANUFACTURERS CODE13499
DESIGN CONTROL REFERENCE662-0278-00


Click here to Register for Free 30-day Trial