5950-00-648-6061 TRANSFORMER,RADIO FREQUENCY Index 5930-00-648-6070 SWITCH,PUSH

National Stock Number:
5950-00-648-6068

Federal Supply Class:
5950

National Item Identification Number:
006486068

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
164-13497485AVIEN INC
E48751181KEYTRONICS, INC.


Techincal Specification:
TERMINAL TYPE AND QUANTITY11 SOLDER STUD
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
21.60 AC VOLTS NOMINAL AND
37.70 AC VOLTS NOMINAL AND
175.70 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
6.30 AC VOLTS NOMINAL AND
18.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
47.20 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODEXTERNAL INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY2 PRIMARY AND
2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH40 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH1.375 INCHES NOMINAL
BODY HEIGHT1.375 INCHES NOMINAL
BODY WIDTH1.375 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
THE MANUFACTURERS DATA
MANUFACTURERS CODE51181
DESIGN CONTROL REFERENCEE487