| TERMINAL TYPE AND QUANTITY | 8 TERMINAL BLOCK W/SCREWS |
| WINDING OPERATING VOLTAGE | 260.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
| 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| WINDING OPERATING CURRENT | 3.25 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT |
| 1.75 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| WINDING POWER RATING | 675.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | FLANGE AND |
| UNTHREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.547 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | OPEN |
| BODY LENGTH | 7.172 INCHES NOMINAL |
| BODY HEIGHT | 3.375 INCHES NOMINAL |
| BODY WIDTH | 6.625 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 03956 |
| DESIGN CONTROL REFERENCE | 27C87-2 |