5950-00-648-5832 TRANSFORMER,AUDIO FREQUENCY Index 5950-00-648-5845 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5950-00-648-5841

Federal Supply Class:
5950

National Item Identification Number:
006485841

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
158504386MAGNETEK INC HUNTINGTON DIV
15850LG51MAGNETEK INC LIGHTING PRODUCTS GROUP
2484973386FREED TRANSFORMER CO
SCC2107380063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
TERMINAL TYPE AND QUANTITY26 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL AND
16.50 AC VOLTS NOMINAL AND
28.00 AC VOLTS NOMINAL AND
39.00 AC VOLTS NOMINAL AND
50.50 AC VOLTS NOMINAL AND
61.00 AC VOLTS NOMINAL AND
73.00 AC VOLTS NOMINAL AND
84.50 AC VOLTS NOMINAL AND
95.50 AC VOLTS NOMINAL AND
107.00 AC VOLTS NOMINAL AND
118.00 AC VOLTS NOMINAL AND
119.50 AC VOLTS NOMINAL AND
120.50 AC VOLTS NOMINAL AND
122.00 AC VOLTS NOMINAL AND
123.00 AC VOLTS NOMINAL AND
124.00 AC VOLTS NOMINAL AND
125.00 AC VOLTS NOMINAL AND
126.00 AC VOLTS NOMINAL AND
127.00 AC VOLTS NOMINAL AND
128.00 AC VOLTS NOMINAL AND
129.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT12.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING50.0 HERTZ NOMINAL OR
60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY2 PRIMARY AND
1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.312 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH18 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH6.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH5.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY HEIGHT9.000 INCHES MAXIMUM
OVERALL LENGTH8.000 INCHES MAXIMUM
OVERALL HEIGHT9.562 INCHES NOMINAL
OVERALL WIDTH7.375 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
THE MANUFACTURERS DATA
MANUFACTURERS CODE80063
DESIGN CONTROL REFERENCESCC21073