5950-00-648-2945 TRANSFORMER,POWER Index 5950-00-648-2959 TRANSFORMER,POWER

National Stock Number:
5950-00-648-2950

Federal Supply Class:
5950

National Item Identification Number:
006482950

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1482A91504ATLAS ENGINEERING CO INC
950-0466-20027777L3 TECHNOLOGIES, INC.
950-0466-40027777L3 TECHNOLOGIES, INC.
EJ72978286SIKORSKY AIRCRAFT CORPORATION
S1655-6178678286SIKORSKY AIRCRAFT CORPORATION


Techincal Specification:
TERMINAL TYPE AND QUANTITY7 SCREW
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHODFLANGE AND
UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEOPEN
BODY LENGTH3.688 INCHES NOMINAL
BODY HEIGHT3.500 INCHES NOMINAL
BODY WIDTH1.625 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
THE MANUFACTURERS DATA
MANUFACTURERS CODE91504
DESIGN CONTROL REFERENCE1482A