| TERMINAL TYPE AND QUANTITY | 7 THREADED STUD |
| WINDING OPERATING VOLTAGE | 34.70 AC VOLTS NOMINAL AND |
| 39.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| WINDING OPERATING CURRENT | 34.5 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING POWER RATING | 1.36 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | SLOT SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING SLOT WIDTH | 0.297 INCHES MINIMUM AND |
| 0.327 INCHES MAXIMUM SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.797 INCHES MINIMUM AND |
| 5.827 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.562 INCHES MINIMUM AND |
| 5.592 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 7.047 INCHES MINIMUM AND |
| 7.077 INCHES MAXIMUM |
| OVERALL HEIGHT | 7.562 INCHES MAXIMUM |
| OVERALL WIDTH | 6.000 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT |