| TERMINAL TYPE AND QUANTITY | 7 STANDOFF, THREADED STUD |
| WINDING OPERATING VOLTAGE | 24.00 AC VOLTS NOMINAL AND |
| 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| 220.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| WINDING OPERATING CURRENT | 6.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED STUD SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY LENGTH | 6.250 INCHES NOMINAL |
| BODY HEIGHT | 6.375 INCHES NOMINAL |
| BODY WIDTH | 5.375 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 91196 |
| DESIGN CONTROL REFERENCE | TP421 |