5950-00-521-1208 TRANSFORMER,POWER Index 5950-00-521-1210 TRANSFORMER,POWER,S

National Stock Number:
5950-00-521-1209

Federal Supply Class:
5950

National Item Identification Number:
005211209

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
2101273386FREED TRANSFORMER CO
BX-936485323BALTIMORE TRANSFORMER CO
C2928-5115280NORTHROP GRUMMAN SYSTEMS CORPORATION DIV ES DEFENSIVE SYSTEMS DIVISION
C2928-5126916NORTHROP GRUMMAN SYSTEMS CORPORATION
C2928-5155631SCOMILL INC


Techincal Specification:
TERMINAL TYPE AND QUANTITY11 STANDOFF, SOLDER LUG
WINDING OPERATING VOLTAGE135.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
430.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
2.70 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
105.00 AC VOLTS NOMINAL AND
117.00 AC VOLTS NOMINAL AND
125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT9.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
270.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
4.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
FREQUENCY RATING60.0 HERTZ MINIMUM AND
400.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH4.500 INCHES NOMINAL
BODY HEIGHT4.875 INCHES NOMINAL
BODY WIDTH3.500 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED


Click here to Register for Free 30-day Trial