| TERMINAL TYPE AND QUANTITY | 10 TAB, SOLDER LUG |
| WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 12.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 25.20 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| WINDING OPERATING CURRENT | 7.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| 2.2 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| 1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| FREQUENCY RATING | 50.0 HERTZ NOMINAL OR |
| 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND |
| 3 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED STUD SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY LENGTH | 4.312 INCHES MAXIMUM |
| BODY HEIGHT | 3.325 INCHES MAXIMUM |
| BODY WIDTH | 3.938 INCHES MAXIMUM |
| OVERALL HEIGHT | 4.812 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 13499 |
| DESIGN CONTROL REFERENCE | 672-0806-00 |