| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 2.100 INCHES MAXIMUM |
| OVERALL LENGTH | 4.315 INCHES MAXIMUM |
| OVERALL WIDTH | 3.855 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 170.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL SINGLE GROUP |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 39.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 65.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING POWER RATING | 2.5 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
| TERMINAL TYPE AND QUANTITY | 7 PIN |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |