| BODY LENGTH | 1.750 INCHES MAXIMUM |
| BODY WIDTH | 1.375 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.360 INCHES MINIMUM AND 1.390 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | OPEN |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 2.000 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.151 INCHES MINIMUM AND 0.161 INCHES MAXIMUM SINGLE GROUP |
| MOUNTING METHOD | UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 250.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 18.60 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 58.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| WINDING POWER RATING | 14.6 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| WINDING POWER RATING | 4.7 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| TERMINAL TYPE AND QUANTITY | 6 TURRET |
| TEST DATA DOCUMENT | 10001-2661896 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |