5950-00-431-3618 COIL,ELECTRICAL Index 4920-00-431-3623 WATER BRAKE ASSY

National Stock Number:
5950-00-431-3619

Federal Supply Class:
5950

National Item Identification Number:
004313619

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
691655-196214RAYTHEON COMPANY


Techincal Specification:
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
BODY LENGTH3.870 INCHES NOMINAL
BODY HEIGHT2.760 INCHES NOMINAL
BODY WIDTH3.220 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY11 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE6.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
34.75 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
47.20 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
199.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
1.5 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
4.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING3.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
52.13 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
188.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODCORE GROUNDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED HOLE SINGLE GROUP